DESIGN AND INSTALLATION

HVAC ENGINEERING
IN UZBEKISTAN

Design, supply, installation and commissioning of air-conditioning, ventilation and heating systems. A DETOS engineer visits the site, conducts a technical survey and prepares a project tailored to your requirements.

SITE SURVEYsurvey terms are agreed
DESIGN + INSTALLATIONone accountable company
PARAMETERS — AS CONFIRMED IN PROJECT DOCUMENTATIONsystem parameters are confirmed by project documentation
SERVICE UNDER CONTRACTmaintenance service
400 kW VRF system installation, Prestige Gardens, Tashkent

WHAT WE INSTALL

FULL-CYCLE HVAC WORKS

We design, supply and install air-conditioning, ventilation and heating systems for commercial and industrial facilities. Every site is different, so equipment is selected for its thermal load, layout and operating profile.

01

VRF / VRV SYSTEMS

Multi-zone variable-refrigerant-flow air-conditioning systems. The number of indoor units and system configuration depend on the selected equipment and are confirmed in the project documentation. This solution is used for business centres, hotels and administrative buildings.

  • Delivered-system parameters — as confirmed in project documentation
  • Simultaneous cooling and heating
  • Room-by-room climate control
VRF system, 400 kW, Prestige Gardens
Chiller system, 30 kW, Piramit Tower
02

CHILLERS & FAN COILS

Central cooling systems based on air- or water-cooled chillers. A solution for large facilities, from business centres to industrial plants.

  • Delivered-system parameters — as confirmed in project documentation
  • Air and water cooling
  • Scalable as the facility grows
03

HEAT PUMPS

Air-to-water and ground-to-water systems provide heating and cooling from a single source. COP and energy consumption depend on the selected documented equipment, design operating points and site conditions. Integration with a solar power system is determined by the project.

  • Heating and cooling from one system
  • Savings depend on the selected equipment, design operating points and operating conditions
  • Integration with a solar power system is determined by the project
VRF system, 120 kW, Renaissance Building
Commercial HVAC installation
04

VENTILATION

Supply-and-extract ventilation units with heat recovery. Industrial ventilation, smoke extraction and air curtains. Designed for applicable sanitary requirements and site-specific conditions.

  • Heat-recovery efficiency depends on the selected documented equipment and operating conditions
  • Design to applicable building and fire-safety requirements
  • CO₂- and humidity-based controls
05

INDUSTRIAL COOLING

LCAC, precision air conditioners and ducted split systems. Solutions for workshops, warehouses, server rooms and retail areas. Thermal-load calculations tailored to specific equipment and processes.

  • Workshops, warehouses and server rooms
  • Continuous operating modes
  • Temperature-control accuracy depends on the selected documented equipment and operating conditions
Chiller, 30 kW, Piramit Tower

VRF. CHILLERS. HEAT PUMPS. VENTILATION. THE SYSTEM TYPE IS DETERMINED BY PROJECT REQUIREMENTS.

PROJECT INFORMATION

FACILITIES IN TASHKENT

Facility materials are supported by project documentation.

PROCESS

SITE WORKFLOW

1

SITE SURVEY

An engineer visits the site to take measurements and assess the layout, thermal load and power supply. Survey terms are agreed in advance.

2

DESIGN

Thermal calculations, equipment selection, pipe routing and control schematics. Coordination with the architect and client.

3

SUPPLY AND INSTALLATION

Equipment is selected according to technical requirements, supply documentation and service availability. Installation follows the agreed design, with installer qualifications documented for the project.

4

COMMISSIONING

Balancing, controls configuration and load testing. Results for each zone are recorded in the commissioning documentation.

5

HANDOVER

As-built documentation, operating instructions and maintenance procedures. The client receives an operational system.

6

MAINTENANCE SERVICE

Seasonal maintenance, diagnostics, repairs and refrigerant top-ups are performed according to the agreed maintenance plan and system condition.

NO OBLIGATION

GET A PROPOSAL FOR YOUR SITE

Leave your number and briefly describe the facility. We will clarify the parameters, conduct a site survey and prepare a project tailored to your requirements.

+998 97 184 00 99

AFTER THE REQUEST

WHAT YOU RECEIVE

Not a generic response. An engineering calculation for your facility with specific solutions.

1

SYSTEM RECOMMENDATION

Which system type is best suited to your facility: VRF, chiller, heat pump or a combination.

2

THERMAL CALCULATION

Room-by-room load calculation, capacity selection and energy-consumption assessment.

3

EQUIPMENT SPECIFICATION

Models, technical specifications, supply documentation, warranty terms and service availability.

4

IMPLEMENTATION TIMELINE

Design, supply and installation — a clear stage-by-stage schedule.

5

ENERGY-EFFICIENCY ASSESSMENT

Comparison of energy consumption using documented baseline data and assessment of operating performance for the selected equipment and conditions.

6

COMMERCIAL OFFER

A document with project scope, DETOS responsibility, and next steps.

FREQUENTLY ASKED QUESTIONS

HVAC — IN BRIEF

What is a VRF system and when is it needed?
VRF (Variable Refrigerant Flow) is a multi-zone air-conditioning system with independent control of indoor units. Their number, configuration and capacity depend on the selected documented equipment and are confirmed in the project documentation. This solution is used for business centres, hotels and administrative buildings.
How does a chiller differ from VRF?
A chiller cools water circulated to fan coils, while VRF uses refrigerant in a piping circuit. System selection and parameters are determined by the design load, facility configuration and documented equipment specifications.
How is the commercial proposal for an HVAC project prepared?
Commercial terms are prepared individually after the technical brief is clarified and the site is surveyed; survey terms are agreed in advance. The facility area, system type, number of zones, routing and controls complexity are taken into account.
What equipment do you supply?
Equipment is selected according to the project’s technical requirements, supply documentation, warranty terms and service availability in Uzbekistan.
How is the feasibility of integrating HVAC with a solar power system determined?
Yes. We coordinate the HVAC electrical load with the solar system specifications. Compatibility and expected benefits are assessed against the facility’s consumption pattern.
What documentation confirms completed HVAC projects?
The scope and parameters of completed HVAC projects are confirmed by design, supply and commissioning documentation. The available document set can be provided for review for a specific project.

READY TO DISCUSSYOUR FACILITY?

Request a calculation for your facility covering the system type, capacity, equipment, stages and commercial terms.

GET YOUR PROPOSAL → TELEGRAM
Call Telegram